IT3000 is a universal industrial weighing terminal ready for the integration in Ethernet networks.
It includes the well proven configurable standard programs:
BASIC for simple weighing systems
COUNT for parts counting
CHECK for simple check scales
FILL for simple filling systems
ONLINE for remote controlled systems
TRUCK/ONLINE for truck scale systems with online PC connection
Parameters can be edited via PC with the IT3000 Configurator PC tool or by means of a web browser directly over the network.
Operation
Operator prompting via 20-character back-lit alphanumeric display. Data entry via sealed membrane keyboard with numeric and function keys.
Weighing Electronics
Integrated signal amplifier for connection of up to 8 strain gauge loadcells using 4- or 6-wire technology
Calibration as single or multiple-range and as single or multi-interval scale
Weights and Measures approved resolution of 6000d with a maximum preload of 80%, 524,000d internal resolution
50 filtered updates / sec
Calibration is made either via display and keyboard of the IT3000 or over the Ethernet interface.
Ethernet interface
Integrated Ethernet interface, with selectable IP address for 10/100BASE-T networks, RJ45 connector
Configuration with PC program 'EtherPort Tool' over the network.
Security
Data is retained in the event of power loss
Password protection
After each weighing cycle weight, date/time and the entered IDs can be stored via Ethernet in a file on a PC's harddisk.
This does not require any specific PC program.
In ONLINE Mode the IT3000 can be remotely controlled from the PC via the Ethernet interface.
The instruction set permits capturing of weight, taring, zero setting and dialog functions.
Any error condition, such as overload, along with date and time is recorded in a log file that can be viewed via web browser.
Storage of data in an internal W&M approved data archive or in a W&M approved file on the PC's harddisk.
Interfaces
One optional serial interface (RS232, RS485 or 20mA CL passive) to connect a printer, remote display or reference scale.
Digital inputs and outputs
Optional PIM module with 2 digital 24V inputs and 2 digital 24V outputs.
Electrical connection
110 (–15%) – 240 (+10%) VAC, wide range input, 50/60 Hz, power consumption max. 15 VA;
Option: 12 – 30 VDC.
Operating temperature
–10°C to +40°C, 95% relative humidity, non-condensing.
Ex version
with ATEX approval for installation in hazardous area, zone 2 (gas) or zone 22 (dust) available as option